MX Series | Crosslinked Acrylic Monodispersed Particles

Product Description

The Chemisnow™ MX Series, developed using our proprietary polymerization technology, consists of acrylic particles with a mean particle diameter of 0.8 to 30 μm. It has high homogeneity and narrow particle size distribution, and also has high heat and solvent resistance due to its crosslinked structure. Due to its high transparency and optical diffusivity, it has been used for many years in products in the optical field, where high quality is required.

MX Series | Crosslinked Acrylic Monodispersed Particles

Features

  • Monodispersed acrylic particles with narrow particle diameter distribution
  • Particle size can be controlled within the range of 0.3 to 30 μm.
  • Excellent heat and solvent resistance due to crosslinked structure
  • Transparency and optical diffusivity
  • High brightness
  • Spherical
  • Low specific gravity compared to inorganic particles

Principal Applications

  • Optical diffusion sheets
  • Anti-glare film
  • Anti-blocking
  • Pore-forming materials
  • Matting agent for paints and inks

Grade and Product Number

*Can be scrolled horizontally

Product no.  Mean particle diameter (μm) Degree of crosslinking Particle size distribution Features
Heat resistance Solvent resistance
MX-30BD 0.3 High Monodispersed ++ ++
MX-80H3wT 0.8 High Monodispersed ++ ++
MX-150 1.5 Standard Monodispersed ++ ++
MX-180TA 1.8 Standard Monodispersed ++ ++
MX-300 3 Standard Monodispersed ++ ++
MX-500L 5 Standard Monodispersed ++ ++
MX-1000 10 Standard Monodispersed ++ ++
MX-1500H 15 High Monodispersed ++ ++
MX-2000 20 Standard Monodispersed ++ ++
MX-3000 30 Standard Monodispersed ++ ++

Properties

Absolute specific gravity 1.19 (Theoretical value)
Bulk density (g/mL) 0.69 (Reference value for MX-1000)
Refractive index 1.49 (Theoretical value)
CV value (%) 9 (Reference value)
Decomposition temperature (°C) 250-270 (Reference value: 10% thermal decomposition in air)
MX-180TA: 300–330°C
  • Note: The data listed are for reference only and are not standard values.
    In addition, there is no guarantee that the listed uses will not infringe on any patents.
Particle Size Distribution Chart for MX-1000
Particle Size Distribution Chart for MX-1000

Contact Us About
Fine Particles

Contact for Fine Particles

+81-3-3983-3187

Email

  • Note: The data listed are for reference only and are not standard values.
    In addition, there is no guarantee that the listed uses will not infringe on any patents.